A Comparative Study of Aortic Wall Stress Using Finite Element Analysis for Ruptured and Non-ruptured Abdominal Aortic Aneurysms*1 (2004)
Journal Article
VENKATASUBRAMANIAM, A., FAGAN, M., MEHTA, T., MYLANKAL, K., RAY, B., KUHAN, G., …MCCOLLUM, P. (2004). A Comparative Study of Aortic Wall Stress Using Finite Element Analysis for Ruptured and Non-ruptured Abdominal Aortic Aneurysms*1. European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery, 28(2), 168-176. https://doi.org/10.1016/S1078-5884%2804%2900178-9

Background. The decision to repair an asymptomatic abdominal aortic aneurysm (AAA) is currently based on diameter (greater than or equal to 5.5 cm) alone. However, aneurysms less than 5.5 cm do rupture while some reach greater than 5.5 cm without rup... Read More about A Comparative Study of Aortic Wall Stress Using Finite Element Analysis for Ruptured and Non-ruptured Abdominal Aortic Aneurysms*1.

A comparative study of aortic wall stress using finite element analysis for ruptured and non-ruptured abdominal aortic aneurysms (2004)
Journal Article
Venkatasubramaniam, A. K., Fagan, M. J., Mehta, T., Mylankal, K. J., Ray, B., Kuhan, G., …McCollum, P. T. (2004). A comparative study of aortic wall stress using finite element analysis for ruptured and non-ruptured abdominal aortic aneurysms. European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery, 28(2), 168-176. https://doi.org/10.1016/j.ejvs.2004.03.029

Background. The decision to repair an asymptomatic abdominal aortic aneurysm (AAA) is currently based on diameter (≥5.5 cm) alone. However, aneurysms less than 5.5 cm do rupture while some reach greater than 5.5 cm without rupturing. Hence the need t... Read More about A comparative study of aortic wall stress using finite element analysis for ruptured and non-ruptured abdominal aortic aneurysms.