On-chip electrochemical detection of glucose towards the miniaturised quality control of carbohydrate-based radiotracers (2020)
Journal Article
Patinglag, L., Esfahani, M. M. N., Ragunathan, K., He, P., Brown, N. J., Archibald, S. J., …Tarn, M. D. (2020). On-chip electrochemical detection of glucose towards the miniaturised quality control of carbohydrate-based radiotracers. Analyst, 145(14), 4920-4930. https://doi.org/10.1039/c9an01881f

The miniaturisation of positron emission tomography (PET) radiotracer production is facilitating a move towards a dose-on-demand strategy that would enable a stratified approach to patient diagnostics, but while the on-chip synthesis steps have been... Read More about On-chip electrochemical detection of glucose towards the miniaturised quality control of carbohydrate-based radiotracers.

Plastic scintillator-based microfluidic devices for miniaturized detection of Positron Emission Tomography radiopharmaceuticals (2018)
Journal Article
Tarn, M. D., Kızılyer, N. Y., Esfahani, M. M. N., Joshi, P., Brown, N. J., Pamme, N., …Archibald, S. J. (2018). Plastic scintillator-based microfluidic devices for miniaturized detection of Positron Emission Tomography radiopharmaceuticals. Chemistry: a European journal, 24(52), 13749-13753. https://doi.org/10.1002/chem.201802395

A miniaturized radio-HPLC detector has been developed comprising a microfluidic device fabricated from plastic scintillator in combination with a silicon photomultiplier light sensor, and tested with samples containing a positron-emitting radionuclid... Read More about Plastic scintillator-based microfluidic devices for miniaturized detection of Positron Emission Tomography radiopharmaceuticals.

Numerical investigation of the energy performance of an Opaque Ventilated Façade system employing a smart modular heat recovery unit and a latent heat thermal energy system (2017)
Journal Article
Diallo, T., Zhao, X., Dugué, A., Bonnamy, P., Miguel, F., Martinez, A., …Brown, N. (2017). Numerical investigation of the energy performance of an Opaque Ventilated Façade system employing a smart modular heat recovery unit and a latent heat thermal energy system. Applied energy, 205, 130-152. https://doi.org/10.1016/j.apenergy.2017.07.042

The building sector is responsible for more than 40% of the EU’s total energy consumption. To reduce the energy consumption in buildings and to achieve the EU’s fossil fuel saving targets for 2020 and beyond 2050, the energy efficient retrofitting st... Read More about Numerical investigation of the energy performance of an Opaque Ventilated Façade system employing a smart modular heat recovery unit and a latent heat thermal energy system.

A disposable microfluidic device with a screen printed electrode for mimicking phase II metabolism (2016)
Journal Article
Vasiliadou, R., Esfahani, M. M. N., Brown, N. J., & Welham, K. J. (2016). A disposable microfluidic device with a screen printed electrode for mimicking phase II metabolism. Sensors, 16(9), Article ARTN 1418. https://doi.org/10.3390/s16091418

Human metabolism is investigated using several in vitro methods. However, the current methodologies are often expensive, tedious and complicated. Over the last decade, the combination of electrochemistry (EC) with mass spectrometry (MS) has a simpler... Read More about A disposable microfluidic device with a screen printed electrode for mimicking phase II metabolism.

Monolith-based68Ga processing: A new strategy for purification to facilitate direct radiolabelling methods (2016)
Journal Article
He, P., Burke, B. P., Clemente, G. S., Brown, N., Pamme, N., & Archibald, S. J. (2016). Monolith-based68Ga processing: A new strategy for purification to facilitate direct radiolabelling methods. Reaction Chemistry and Engineering, 1(4), 361-365. https://doi.org/10.1039/c6re00081a

The post-processing of68Ga generator eluate by means of a novel high capacity cation-exchange silica monolith column has been validated in this work. Quantitative release of a purified68Ga solution in high concentration can be achieved using weak aci... Read More about Monolith-based68Ga processing: A new strategy for purification to facilitate direct radiolabelling methods.

Development of radiodetection systems towards miniaturised quality control of PET and SPECT radiopharmaceuticals (2016)
Journal Article
Taggart, M. P., Tarn, M. D., Esfahani, M. M. N., Schofield, D. M., Brown, N. J., Archibald, S. J., …Thompson, L. F. (2016). Development of radiodetection systems towards miniaturised quality control of PET and SPECT radiopharmaceuticals. Lab on a chip, 16(9), 1605-1616. https://doi.org/10.1039/c6lc00099a

The ability to detect radiation in microfluidic devices is important for the on-chip analysis of radiopharmaceuticals, but previously reported systems have largely suffered from various limitations including cost, complexity of fabrication, and insuf... Read More about Development of radiodetection systems towards miniaturised quality control of PET and SPECT radiopharmaceuticals.

Positron detection in silica monoliths for miniaturised quality control of PET radiotracers (2016)
Journal Article
Tarn, M. D., Maneuski, D., Alexander, R., Brown, N. J., O’Shea, V., Pimlott, S. L., …Archibald, S. J. (2016). Positron detection in silica monoliths for miniaturised quality control of PET radiotracers. Chemical communications : Chem comm / the Royal Society of Chemistry, 52(45), 7221-7224. https://doi.org/10.1039/c6cc00660d

We demonstrate the use of the miniaturised Medipix positron sensor for detection of the clinical PET radiotracer, [⁶⁸Ga]gallium-citrate, on a silica-based monolith, towards microfluidic quality control. The system achieved a far superior signal-to-no... Read More about Positron detection in silica monoliths for miniaturised quality control of PET radiotracers.