Skip to main content

Research Repository

Advanced Search

All Outputs (17)

Validation of an algorithm to reveal the U wave in atrial fibrillation (2018)
Journal Article
Al-Karadi, M. S., Wilkinson, A. J., Caldwell, J., & Langley, P. (2018). Validation of an algorithm to reveal the U wave in atrial fibrillation. Scientific reports, 8(1), Article 11946. https://doi.org/10.1038/s41598-018-30493-8

Major cardiac organisations recommend U wave abnormalities should be reported during ECG interpretation. However, U waves cannot be measured in patients with atrial fibrillation (AF) due to the obscuring fibrillatory wave. The aim was to validate a U... Read More about Validation of an algorithm to reveal the U wave in atrial fibrillation.

Novel non-invasive algorithm to identify the origins of re-entry and ectopic foci in the atria from 64-lead ECGs. A computational study (2017)
Journal Article
Alday, E. A. P., Colman, M. A., Langley, P., & Zhang, H. (2017). Novel non-invasive algorithm to identify the origins of re-entry and ectopic foci in the atria from 64-lead ECGs. A computational study. PLoS Computational Biology, 13(3), e1005270. https://doi.org/10.1371/journal.pcbi.1005270

Atrial tachy-arrhytmias, such as atrial fibrillation (AF), are characterised by irregular electrical activity in the atria, generally associated with erratic excitation underlain by re-entrant scroll waves, fibrillatory conduction of multiple wavelet... Read More about Novel non-invasive algorithm to identify the origins of re-entry and ectopic foci in the atria from 64-lead ECGs. A computational study.

Accuracy of pulse interval timing in ambulatory blood pressure measurement (2016)
Journal Article
Kane, S. A., Blake, J. R., McArdle, F. J., Langley, P., & Sims, A. J. (2016). Accuracy of pulse interval timing in ambulatory blood pressure measurement. Scientific reports, 6(1), Article 37472. https://doi.org/10.1038/srep37472

Blood pressure (BP) monitors rely on pulse detection. Some blood pressure monitors use pulse timings to analyse pulse interval variability for arrhythmia screening, but this assumes that the pulse interval timings detected from BP cuffs are accurate... Read More about Accuracy of pulse interval timing in ambulatory blood pressure measurement.

A study on stability analysis of atrial repolarization variability using ARX model in sinus rhythm and atrial tachycardia ECGs (2016)
Journal Article
Sivaraman, J., Uma, G., Langley, P., Umapathy, M., Venkatesan, S., & Palanikumar, G. (2016). A study on stability analysis of atrial repolarization variability using ARX model in sinus rhythm and atrial tachycardia ECGs. Computer Methods and Programs in Biomedicine, 137, 341-351. https://doi.org/10.1016/j.cmpb.2016.10.005

© 2016 Elsevier Ireland Ltd Background The interaction between the PTa and PP interval dynamics from the surface ECG is seldom explained. Mathematical modeling of these intervals is of interest in finding the relationship between the heart rate and r... Read More about A study on stability analysis of atrial repolarization variability using ARX model in sinus rhythm and atrial tachycardia ECGs.

A non-invasive, home-based EEG hypoglycaemia warning system for personal monitoring using skin surface electrodes : a single-case feasibility study (2016)
Journal Article
Clewett, C. J., Langley, P., Bateson, A. D., Asghar, A., & Wilkinson, A. J. (2016). A non-invasive, home-based EEG hypoglycaemia warning system for personal monitoring using skin surface electrodes : a single-case feasibility study. Health Technology Letters, 3(1), 2-5. https://doi.org/10.1049/htl.2015.0037

Hypoglycaemia unawareness is a common condition associated with increased risk of severe hypoglycaemia. The purpose of the authors' study was to develop a simple to use, home-based and non-invasive hypoglycaemia warning system based on electroencepha... Read More about A non-invasive, home-based EEG hypoglycaemia warning system for personal monitoring using skin surface electrodes : a single-case feasibility study.

Wavelet entropy as a measure of ventricular beat suppression from the electrocardiogram in atrial fibrillation (2015)
Journal Article
Langley, P. (2015). Wavelet entropy as a measure of ventricular beat suppression from the electrocardiogram in atrial fibrillation. Entropy, 17(9), 6397-6411. https://doi.org/10.3390/e17096397

A novel method of quantifying the effectiveness of the suppression of ventricular activity from electrocardiograms (ECGs) in atrial fibrillation is proposed. The temporal distribution of the energy of wavelet coefficients is quantified by wavelet ent... Read More about Wavelet entropy as a measure of ventricular beat suppression from the electrocardiogram in atrial fibrillation.

Effect of catheter ablation on quality of life in patients with atrial fibrillation and its correlation with arrhythmia outcome (2015)
Journal Article
Raine, D., Langley, P., Shepherd, E., Lord, S., Murray, S., Murray, A., & Bourke, J. P. (2015). Effect of catheter ablation on quality of life in patients with atrial fibrillation and its correlation with arrhythmia outcome. Open heart, 2(1), e000302. https://doi.org/10.1136/openhrt-2015-000302

Objective To assess the effect of catheter ablation on atrial fibrillation (AF) symptoms and quality of life (QoL). Methods Patients with AF scheduled for ablation were recruited. Pulmonary vein isolation (PVI) was performed and complex fractionated... Read More about Effect of catheter ablation on quality of life in patients with atrial fibrillation and its correlation with arrhythmia outcome.

Principal component analysis of atrial fibrillation: Inclusion of posterior ECG leads does not improve correlation with left atrial activity (2015)
Journal Article
Raine, D., Langley, P., Shepherd, E., Lord, S., Murray, S., Murray, A., & Bourke, J. P. (2015). Principal component analysis of atrial fibrillation: Inclusion of posterior ECG leads does not improve correlation with left atrial activity. Medical engineering & physics, 37(2), 251-255. https://doi.org/10.1016/j.medengphy.2014.12.008

Background Lead V₁ is routinely analysed due to its large amplitude AF waveform. V₁ correlates strongly with right atrial activity but only moderately with left atrial activity. Posterior lead V₉ correlates strongest with left atrial activity. Aims (... Read More about Principal component analysis of atrial fibrillation: Inclusion of posterior ECG leads does not improve correlation with left atrial activity.

A new algorithm to diagnose atrial ectopic origin from multi lead ECG systems - insights from 3D virtual human atria and torso (2015)
Journal Article
Alday, E. A. P., Colman, M. A., Langley, P., Butters, T. D., Higham, J., Workman, A. J., …Zhang, H. (2015). A new algorithm to diagnose atrial ectopic origin from multi lead ECG systems - insights from 3D virtual human atria and torso. PLoS Computational Biology, 11(1), Article e1004026. https://doi.org/10.1371/journal.pcbi.1004026

Rapid atrial arrhythmias such as atrial fibrillation (AF) predispose to ventricular arrhythmias, sudden cardiac death and stroke. Identifying the origin of atrial ectopic activity from the electrocardiogram (ECG) can help to diagnose the early onset... Read More about A new algorithm to diagnose atrial ectopic origin from multi lead ECG systems - insights from 3D virtual human atria and torso.

Characteristics of the atrial repolarization phase of the ECG in paroxysmal atrial fibrillation patients and controls (2015)
Journal Article
Langley, P., Bourke, J. P., & Giacopelli, D. (2015). Characteristics of the atrial repolarization phase of the ECG in paroxysmal atrial fibrillation patients and controls. Acta Cardiologica, 70(6), 672-677. https://doi.org/10.2143/AC.70.6.3120179

© 2015, Acta Cardiologica. All rights reserved. Objective The aim of this study is to characterize the observable segment of the atrial repolarization (Ta wave) of the standard ECG during sinus rhythm in paroxysmal atrial fibrillation (PAF) patients... Read More about Characteristics of the atrial repolarization phase of the ECG in paroxysmal atrial fibrillation patients and controls.

Non-invasive estimation of left atrial dominant frequency in atrial fibrillation from different electrode sites: Insight from body surface potential mapping (2014)
Journal Article
Bojarnejad, M., Blake, J. R., Bourke, J., Shepherd, E., Murray, A., & Langley, P. (2014). Non-invasive estimation of left atrial dominant frequency in atrial fibrillation from different electrode sites: Insight from body surface potential mapping. Journal of atrial fibrillation, 7(3), 6-10

© 2014, CardioFront LLC. All rights reserved. The dominant driving sources of atrial fibrillation are often found in the left atrium, but the expression of left atrial activation on the body surface is poorly understood. Using body surface potential... Read More about Non-invasive estimation of left atrial dominant frequency in atrial fibrillation from different electrode sites: Insight from body surface potential mapping.

Recurring patterns of atrial fibrillation in surface ECG predict restoration of sinus rhythm by catheter ablation (2014)
Journal Article
Di Marco, L. Y., Raine, D., Bourke, J. P., & Langley, P. (2014). Recurring patterns of atrial fibrillation in surface ECG predict restoration of sinus rhythm by catheter ablation. Computers in biology and medicine, 54, 172-179. https://doi.org/10.1016/j.compbiomed.2014.09.005

Background Non-invasive tools to help identify patients likely to benefit from catheter ablation (CA) of atrial fibrillation (AF) would facilitate personalised treatment planning. Aim To investigate atrial waveform organisation through recurrence plo... Read More about Recurring patterns of atrial fibrillation in surface ECG predict restoration of sinus rhythm by catheter ablation.

Recurring patterns in stationary intervals of abdominal uterine electromyograms during gestation (2014)
Journal Article
Di Marco, L. Y., Di Maria, C., Tong, W., Taggart, M. J., Robson, S. C., & Langley, P. (2014). Recurring patterns in stationary intervals of abdominal uterine electromyograms during gestation. Medical and Biological Engineering and Computing, 52(8), 707-716. https://doi.org/10.1007/s11517-014-1174-6

Abdominal uterine electromyograms (uEMG) studies have focused on uterine contractions to describe the evolution of uterine activity and preterm birth (PTB) prediction. Stationary, non-contracting uEMG has not been studied. The aim of the study was to... Read More about Recurring patterns in stationary intervals of abdominal uterine electromyograms during gestation.

Characteristics of atrial fibrillation cycle length predict restoration of sinus rhythm by catheter ablation (2013)
Journal Article
Di Marco, L. Y., Raine, D., Bourke, J. P., & Langley, P. (2013). Characteristics of atrial fibrillation cycle length predict restoration of sinus rhythm by catheter ablation. Heart rhythm : the official journal of the Heart Rhythm Society, 10(9), 1303-1310. https://doi.org/10.1016/j.hrthm.2013.06.007

Background Successful termination of atrial fibrillation (AF) during catheter ablation (CA) is associated with arrhythmia-free follow-up. Preablation factors such as mean atrial fibrillation cycle length (AFCL) predict the likelihood of AF terminatio... Read More about Characteristics of atrial fibrillation cycle length predict restoration of sinus rhythm by catheter ablation.

Accuracy of algorithms for detection of atrial fibrillation from short duration beat interval recordings (2012)
Journal Article
Langley, P., Dewhurst, M., Di Marco, L. Y., Adams, P., Dewhurst, F., Mwita, J. C., …Murray, A. (2012). Accuracy of algorithms for detection of atrial fibrillation from short duration beat interval recordings. Medical engineering & physics, 34(10), 1441-1447. https://doi.org/10.1016/j.medengphy.2012.02.002

Atrial fibrillation (AF) is characterised by highly variable beat intervals. The aims of the study were to assess the accuracy of AF detection algorithms from short analysis durations and to validate prospectively the accuracy on a large community-ba... Read More about Accuracy of algorithms for detection of atrial fibrillation from short duration beat interval recordings.

Circadian variation of human ventricular fibrillation dominant frequency (2010)
Journal Article
Langley, P., MacGowan, G. A., & Murray, A. (2010). Circadian variation of human ventricular fibrillation dominant frequency. Resuscitation, 81(8), 950-955. https://doi.org/10.1016/j.resuscitation.2010.03.026

Aim Circadian variation in human ventricular fibrillation (VF) dominant frequency is unknown. If present this would provide evidence of physiological influence on VF. The objective was to quantify the circadian variation in human VF dominant frequen... Read More about Circadian variation of human ventricular fibrillation dominant frequency.

Principal component analysis as a tool for analyzing beat-to-beat changes in ECG features: application to ECG-derived respiration (2009)
Journal Article
Langley, P., Bowers, E. J., & Murray, A. (2010). Principal component analysis as a tool for analyzing beat-to-beat changes in ECG features: application to ECG-derived respiration. IEEE transactions on bio-medical engineering / Bio-medical Engineering Group, 57(4), 821-829. https://doi.org/10.1109/TBME.2009.2018297

An algorithm for analyzing changes in ECG morphology based on principal component analysis (PCA) is presented and applied to the derivation of surrogate respiratory signals from single-lead ECGs. The respiratory-induced variability of ECG features, P... Read More about Principal component analysis as a tool for analyzing beat-to-beat changes in ECG features: application to ECG-derived respiration.