Skip to main content

Research Repository

Advanced Search

All Outputs (8)

Correction: On-chip polyelectrolyte coating onto magnetic droplets – towards continuous flow assembly of drug delivery capsules (2017)
Journal Article
Alorabi, A. Q., Tarn, M. D., Gómez-Pastora, J., Bringas, E., Ortiz, I., Paunov, V. N., & Pamme, N. (2017). Correction: On-chip polyelectrolyte coating onto magnetic droplets – towards continuous flow assembly of drug delivery capsules. Lab on a chip, 17(22), 3934. https://doi.org/10.1039/c7lc90110k

Correction for ‘On-chip polyelectrolyte coating onto magnetic droplets – towards continuous flow assembly of drug delivery capsules’ by Ali Q. Alorabi et al., Lab Chip, 2017, DOI: 10.1039/c7lc00918f.

Fabrication of tailorable pH responsive cationic amphiphilic microgels on a microfluidic device for drug release (2017)
Journal Article
Lu, B., Tarn, M. D., Pamme, N., & Georgiou, T. K. (2018). Fabrication of tailorable pH responsive cationic amphiphilic microgels on a microfluidic device for drug release. Journal of Polymer Science Part A: Polymer Chemistry, 56(1), 59-66. https://doi.org/10.1002/pola.28860

Cationic, amphiphilic microgels of differing compositions based on hydrophilic, pH, and thermoresponsive 2-(dimethylamino)ethyl methacrylate (DMAEMA) and hydrophobic, nonionic n-butyl acrylate (BuA) are synthesized using a lab-on-a-chip device. Hydro... Read More about Fabrication of tailorable pH responsive cationic amphiphilic microgels on a microfluidic device for drug release.

On-chip polyelectrolyte coating onto magnetic droplets – towards continuous flow assembly of drug delivery capsules (2017)
Journal Article
Alorabi, A. Q., Tarn, M. D., Gómez-Pastora, J., Bringas, E., Ortiz, I., Paunov, V. N., & Pamme, N. (2017). On-chip polyelectrolyte coating onto magnetic droplets – towards continuous flow assembly of drug delivery capsules. Lab on a chip, 17(22), 3785-3795. https://doi.org/10.1039/c7lc00918f

Polyelectrolyte (PE) microcapsules for drug delivery are typically fabricated via layer-by-layer (LbL) deposition of PE layers of alternating charge on sacrificial template microparticles, which usually requires multiple incubation and washing steps... Read More about On-chip polyelectrolyte coating onto magnetic droplets – towards continuous flow assembly of drug delivery capsules.

Surface enhanced Raman spectroscopy for single molecule detection and biosensing (2017)
Thesis
Marshall, A. R. L. (2017). Surface enhanced Raman spectroscopy for single molecule detection and biosensing. (Thesis). University of Hull. Retrieved from https://hull-repository.worktribe.com/output/4220864

The aim of this thesis is to design plasmonic nano-gaps capable of detecting materials down to sufficiently low concentrations such that single molecule characteristics are observed. We begin first, by discussing the theory of plasmonics. Then, we as... Read More about Surface enhanced Raman spectroscopy for single molecule detection and biosensing.

A microfluidic device for rapid screening of E. coli O157:H7 based on IFAST and ATP bioluminescence assay for water analysis (2017)
Journal Article
Ngamsom, B., Truyts, A., Fourie, L., Kumar, S., Tarn, M. D., Iles, A., …Pamme, N. (2017). A microfluidic device for rapid screening of E. coli O157:H7 based on IFAST and ATP bioluminescence assay for water analysis. Chemistry: a European journal, 23(52), 12754-12757. https://doi.org/10.1002/chem.201703487

© 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim We present a simple microfluidic system for rapid screening of Escherichia coli (E. coli) O157:H7 employing the specificity of immunomagnetic separation (IMS) via immiscible filtration assisted by s... Read More about A microfluidic device for rapid screening of E. coli O157:H7 based on IFAST and ATP bioluminescence assay for water analysis.

Definition of a magnetic susceptibility of conglomerates with magnetite particles. Particularities of defining single particle susceptibility (2017)
Journal Article
Sandulyak, A. A., Sandulyak, A. V., Ershova, V., Pamme, N., Ngmasom, B., & Iles, A. (2017). Definition of a magnetic susceptibility of conglomerates with magnetite particles. Particularities of defining single particle susceptibility. Journal of Magnetism and Magnetic Materials, 441, 724-734. https://doi.org/10.1016/j.jmmm.2017.06.027

Data of a magnetic susceptibility of ferro-and the ferrimagnetic particles of many technogenic, natural, special media are especially demanded for the solution of various tasks connected with purposeful magnetic impact on these particles. One of prod... Read More about Definition of a magnetic susceptibility of conglomerates with magnetite particles. Particularities of defining single particle susceptibility.

Magnetic particles-based chemiluminescence immunoassay for progesterone determination (2017)
Journal Article
Phakthong, W., Greenway, G. M., Pamme, N., Liawruangrath, B., & Liawruangrath, S. (2017). Magnetic particles-based chemiluminescence immunoassay for progesterone determination. Wārasān Khana Witthayāsāt, Mahāwitthayālai Chīang Mai = Journal of the Science Faculty of Chiang Mai University / Mahāwitthayālai Chīang Mai, 44(1), 215-223

© 2017, Chiang Mai University. All rights reserved. A magnetic particles-based chemiluminescence immunoassay was investigated for progesterone detection by using luminometer. In this work, progesterone was determined based on the competitive binding... Read More about Magnetic particles-based chemiluminescence immunoassay for progesterone determination.

On-chip magnetic particle-based immunoassays using multilaminar flow for clinical diagnostics (2017)
Book Chapter
Tarn, M. D., & Pamme, N. (2017). On-chip magnetic particle-based immunoassays using multilaminar flow for clinical diagnostics. In V. Taly, J. L. Viovy, & S. Descroix (Eds.), Microchip Diagnostics : Methods and Protocols (69-83). New York: Humana Press. https://doi.org/10.1007/978-1-4939-6734-6_6

Magnetic particles have become popular in recent years for immunoassays due to their high surface-to-volume ratio and the ease of their manipulation. However, such assays also require multiple reaction and washing steps that are both time-consuming a... Read More about On-chip magnetic particle-based immunoassays using multilaminar flow for clinical diagnostics.