Skip to main content

Research Repository

Advanced Search

All Outputs (6)

Erratum: Cranial sutures work collectively to distribute strain throughout the reptile skull (Journal of The Royal Society Interface (2013) 10 (2013044) DOI: 10.1098/rsif.2013.0442) (2013)
Journal Article
Curtis, N., Jones, M. E., Evans, S. E., O'Higgins, P., & Fagan, M. J. (2013). Erratum: Cranial sutures work collectively to distribute strain throughout the reptile skull (Journal of The Royal Society Interface (2013) 10 (2013044) DOI: 10.1098/rsif.2013.0442). Journal of the Royal Society interface / the Royal Society, 10(87), Article 2013044. https://doi.org/10.1098/rsif.2013.0584

Figure 4 was presented incorrectly, with (a) and (b) displaying the same bite position. The corrected figure below shows different bite positions for (a) and (b) as was initially intended.

The importance of accurate muscle modelling for biomechanical analyses: A case study with a lizard skull (2013)
Journal Article
Gröning, F., Jones, M. E., Curtis, N., Herrel, A., O'Higgins, P., Evans, S. E., & Fagan, M. J. (2013). The importance of accurate muscle modelling for biomechanical analyses: A case study with a lizard skull. Journal of the Royal Society interface / the Royal Society, 10(84), Article 20130216. https://doi.org/10.1098/rsif.2013.0216

Computer-based simulation techniques such as multi-body dynamics analysis are becoming increasingly popular in the field of skull mechanics. Multi-body models can be used for studying the relationships between skull architecture, muscle morphology an... Read More about The importance of accurate muscle modelling for biomechanical analyses: A case study with a lizard skull.

Cranial sutures work collectively to distribute strain throughout the reptile skull (2013)
Journal Article
Curtis, N., Fagan, M. J., Evans, S. E., Jones, M. E. H., & O'Higgins, P. (2013). Cranial sutures work collectively to distribute strain throughout the reptile skull. Journal of the Royal Society interface / the Royal Society, 10(86), 1-9. https://doi.org/10.1098/rsif.2013.0442

The skull is composed of many bones that come together at sutures. These sutures are important sites of growth, and as growth ceases some become fused while others remain patent. Their mechanical behaviour and how they interact with changing form and... Read More about Cranial sutures work collectively to distribute strain throughout the reptile skull.

In situ study of the evolution of atomic strain of bulk metallic glass and its effects on shear band formation (2013)
Journal Article
Huang, Y. J., Khong, J. C., Connolley, T., & Mi, J. (2013). In situ study of the evolution of atomic strain of bulk metallic glass and its effects on shear band formation. Scripta materialia, 69(3), 207-210. https://doi.org/10.1016/j.scriptamat.2013.03.016

The tensile behavior of TiZrNiCuBe metallic glass was studied using synchrotron X-ray diffraction and scanning electron microscopy. Shear band formation was carefully controlled by the introduction of a stress gradient due to a semi-circular notch. M... Read More about In situ study of the evolution of atomic strain of bulk metallic glass and its effects on shear band formation.

High speed imaging study of the dynamics of ultrasonic bubbles at a liquid-solid interface (2013)
Presentation / Conference Contribution
Tan, D., & Mi, J. High speed imaging study of the dynamics of ultrasonic bubbles at a liquid-solid interface

High speed imaging, including the ultrafast synchrotron X-ray imaging facility at the beamline 32-ID-B of the Advanced Photon Source (APS), was used to study in-situ (1) the dynamics of ultrasonic bubbles inside a water suspension with an acoustic fi... Read More about High speed imaging study of the dynamics of ultrasonic bubbles at a liquid-solid interface.

Ultrafast X-ray imaging and modelling of ultrasonic cavitations in liquid metal (2013)
Presentation / Conference Contribution
Lee, T. L., Khong, J. C., Fezzaa, K., & Mi, J. Ultrafast X-ray imaging and modelling of ultrasonic cavitations in liquid metal

The dynamics of ultrasonic bubbles in liquid metal are captured in-situ for the first time using the ultrafast X-ray phase contrast imaging facility housed at the Advanced Photon Source, Argonne National Laboratory, in the USA. The experimental obser... Read More about Ultrafast X-ray imaging and modelling of ultrasonic cavitations in liquid metal.