Skip to main content

Research Repository

Advanced Search

All Outputs (2)

A disposable microfluidic device with a screen printed electrode for mimicking phase II metabolism (2016)
Journal Article
Vasiliadou, R., Esfahani, M. M. N., Brown, N. J., & Welham, K. J. (2016). A disposable microfluidic device with a screen printed electrode for mimicking phase II metabolism. Sensors, 16(9), Article ARTN 1418. https://doi.org/10.3390/s16091418

Human metabolism is investigated using several in vitro methods. However, the current methodologies are often expensive, tedious and complicated. Over the last decade, the combination of electrochemistry (EC) with mass spectrometry (MS) has a simpler... Read More about A disposable microfluidic device with a screen printed electrode for mimicking phase II metabolism.

Positron detection in silica monoliths for miniaturised quality control of PET radiotracers (2016)
Journal Article
Tarn, M. D., Maneuski, D., Alexander, R., Brown, N. J., O’Shea, V., Pimlott, S. L., …Archibald, S. J. (2016). Positron detection in silica monoliths for miniaturised quality control of PET radiotracers. Chemical communications : Chem comm / the Royal Society of Chemistry, 52(45), 7221-7224. https://doi.org/10.1039/c6cc00660d

We demonstrate the use of the miniaturised Medipix positron sensor for detection of the clinical PET radiotracer, [⁶⁸Ga]gallium-citrate, on a silica-based monolith, towards microfluidic quality control. The system achieved a far superior signal-to-no... Read More about Positron detection in silica monoliths for miniaturised quality control of PET radiotracers.