Off-design performance modelling of a solar organic Rankine cycle integrated with pressurized hot water storage unit for community level application

Kutlu, Cagri; Li, Jing; Su, Yuehong; Pei, Gang; Riffat, Saffa

Authors

Cagri Kutlu

Yuehong Su

Gang Pei

Saffa Riffat



Abstract

Solar organic Rankine cycle (ORC) has advantages over common PV systems in view of the flexible operation even if solar radiation is unavailable. However, at present the dynamic performance of solar ORC with respect to the off-design behaviour of storage unit, expander, pump and heat exchanger is rarely reported. This paper investigates a medium-temperature solar ORC system characterized by evacuated flat-plate collectors and pressurised water storage unit. The main aim of the study is to investigate the performance of the system with consideration of transient behaviour of the thermal storage unit which results in off-design operation of other components. The other aim is adjusting the power output according to electricity demand throughout a day. The heat storage unit is analysed using one-dimensional temperature distribution model. A transient simulation model is developed including pump and expander models. To meet the electrical demands of different periods, the mass flow rate of heat source is adjusted for controlling the evaporation temperature. Moreover, sliding pressure operation control strategy of the ORC is implemented to meet variable heat source temperature. A 550 m2 solar collector area and a 4 m diameter and 7 m height pressurized water cylinder are used in simulation. Produced work is controlled and the results are matched with the demands. Produced work from the expander under the given conditions are 47.11 kWh in day time, 70.97 kWh in peak period and 31.59 kWh after midnight.

Citation

Kutlu, C., Li, J., Su, Y., Pei, G., & Riffat, S. (2018). Off-design performance modelling of a solar organic Rankine cycle integrated with pressurized hot water storage unit for community level application. Energy Conversion and Management, 166, 132-145. https://doi.org/10.1016/j.enconman.2018.04.024

Journal Article Type Article
Acceptance Date Apr 7, 2018
Online Publication Date May 3, 2018
Publication Date Jun 15, 2018
Deposit Date Mar 24, 2022
Journal Energy Conversion and Management
Print ISSN 0196-8904
Publisher Elsevier
Peer Reviewed Peer Reviewed
Volume 166
Pages 132-145
DOI https://doi.org/10.1016/j.enconman.2018.04.024
Keywords Solar ORC; Off-design analysis; Heat storage unit; Control strategy; Power output