Skip to main content

Research Repository

Advanced Search

Electrochemical immunoassay for the detection of stress biomarkers

Abdulsattar, Jwan O.; Greenway, Gillian M.; Wadhawan, Jay D.

Authors

Jwan O. Abdulsattar

Gillian M. Greenway



Contributors

Abstract

A rapid electrochemical immunoassay method was developed to detect and measure stress biomarkers (cortisol and cortisone) in two biological samples (Zebrafish whole-body and artificial saliva). This methodology utilizes an immunoassay approach taking advantage of the lock and key mechanism that is related to the antibody-antigen interaction depending on the reliable immobilization of the antibody labelled with ferrocene tags (Ab-Fc) on a modified tin-doped indium oxide (ITO) electrode using electrochemical instrumentation to build a POC platform. The limit of detection (LOD) obtained for this biosensor was 1.03 pg ml−1 for cortisol and 0.68 pg ml−1 for cortisone, respectively. The correlation coefficient was 0.9852 and 0.9841 for cortisol and cortisone, respectively with a linear concentration from (0-50 ng ml−1) which covers the standard levels of stress hormones in both selected biological samples. The incubation time was investigated and 30 min was found to be the optimum incubation time. This time would be acceptable for the POC system as total process time can be determined within 35 min.

Citation

Abdulsattar, J. O., Greenway, G. M., & Wadhawan, J. D. (2020). Electrochemical immunoassay for the detection of stress biomarkers. Heliyon, 6(3), Article e03558. https://doi.org/10.1016/j.heliyon.2020.e03558

Journal Article Type Article
Acceptance Date Mar 4, 2020
Online Publication Date Mar 18, 2020
Publication Date 2020-03
Deposit Date Apr 14, 2020
Publicly Available Date Apr 15, 2020
Journal Heliyon
Print ISSN 2405-8440
Publisher Elsevier
Peer Reviewed Peer Reviewed
Volume 6
Issue 3
Article Number e03558
DOI https://doi.org/10.1016/j.heliyon.2020.e03558
Keywords Biomedical engineering; Electrochemistry; BiosensorsImmunoassay; Stress biomarkers; Point of care
Public URL https://hull-repository.worktribe.com/output/3496714
Publisher URL https://www.cell.com/heliyon/fulltext/S2405-8440(20)30403-5
Related Public URLs https://www.sciencedirect.com/science/article/pii/S2405844020304035
Additional Information This article is maintained by: Elsevier; Article Title: Electrochemical immunoassay for the detection of stress biomarkers; Journal Title: Heliyon; CrossRef DOI link to publisher maintained version: https://doi.org/10.1016/j.heliyon.2020.e03558; Content Type: article; Copyright: Crown Copyright © 2020 Published by Elsevier Ltd.