S. Malek
Computer assisted orthopaedic surgical system for insertion of distal locking screws in intra-medullary nails: a valid and reliable navigation system
Malek, S.; Phillips, R.; Mohsen, A.; Viant, W.; Bielby, M.; Sherman, K.
Authors
Abstract
The insertion of distal locking screws is a difficult task in intra-medullary (IM) nailing operations of long bones and contributes a significant proportion to the overall operating time. The current technique to insert these screws uses numerous fluoroscopic images and depends on the skills and expertise of the surgeon. The Computer Assisted Orthopaedic Surgical System (CAOSS) was developed to assist orthopaedic surgeons in these operations. The laboratory based test results for insertion of distal locking screws in IM nailing procedures are presented and discussed in terms of accuracy and as part of the validation process to introduce new CAOS procedures into clinical use. This study shows that CAOSS in IM nailing is robust and reliable. Positional accuracy was shown to be within 0.3 mm and angular accuracy within 0.2 degrees with femoral IM nail. CAOSS was also shown to be very reliable and accurate at different angles of distal screws in fluoroscopic image space. Copyright 2005 John Wiley & Sons, Ltd.
Citation
Malek, S., Phillips, R., Mohsen, A., Viant, W., Bielby, M., & Sherman, K. (2005). Computer assisted orthopaedic surgical system for insertion of distal locking screws in intra-medullary nails: a valid and reliable navigation system. International Journal of Medical Robotics and Computer Assisted Surgery, 1(4), 34-44. https://doi.org/10.1002/rcs.54
Journal Article Type | Article |
---|---|
Online Publication Date | Apr 5, 2006 |
Publication Date | 2005-12 |
Journal | INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY |
Print ISSN | 1478-5951 |
Publisher | Wiley |
Peer Reviewed | Peer Reviewed |
Volume | 1 |
Issue | 4 |
Pages | 34-44 |
DOI | https://doi.org/10.1002/rcs.54 |
Keywords | Biophysics; Surgery; Computer Science Applications |
Public URL | https://hull-repository.worktribe.com/output/391635 |
Publisher URL | https://onlinelibrary.wiley.com/doi/abs/10.1002/rcs.54 |
You might also like
A phantom based approach to fluoroscopic navigation for orthopaedic surgery
(2004)
Book Chapter
Recovery of distal hole axis in intramedullary nail trajectory planning
(-0001)
Presentation / Conference Contribution
Desktop-based computer-assisted orthopedic training system for spinal surgery
(2014)
Journal Article
Computer-assisted orthopedic training system for fracture fixation
(2013)
Journal Article
Downloadable Citations
About Repository@Hull
Administrator e-mail: repository@hull.ac.uk
This application uses the following open-source libraries:
SheetJS Community Edition
Apache License Version 2.0 (http://www.apache.org/licenses/)
PDF.js
Apache License Version 2.0 (http://www.apache.org/licenses/)
Font Awesome
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2024
Advanced Search