Peak wall stress measurement in elective and acute abdominal aortic aneurysms (2007)
Journal Article
Heng, M. S., Fagan, M. J., Collier, J. W., Desai, G., McCollum, P. T., & Chetter, I. C. (2008). Peak wall stress measurement in elective and acute abdominal aortic aneurysms. Journal of vascular surgery, 47(1), 17-22. https://doi.org/10.1016/j.jvs.2007.09.002

Background: Abdominal aortic aneurysm (AAA) rupture occurs when wall stress exceeds wall strength. Engineering principles suggest that aneurysm diameter is only one aspect of its geometry that influences wall stress. Finite element analysis considers... Read More about Peak wall stress measurement in elective and acute abdominal aortic aneurysms.

Conduction-band crossover induced by misfit strain in InSb/GaSb self-assembled quantum dots (2007)
Journal Article
Rybchenko, S. I., Gupta, R., Lai, K. T., Itskevich, I. E., Haywood, S. K., Tasco, V., Deguffroy, N., Baranov, A. N., & Tournié, E. (2007). Conduction-band crossover induced by misfit strain in InSb/GaSb self-assembled quantum dots. Physical review B: Condensed matter and materials physics, 76(19), 0 - 0. https://doi.org/10.1103/physrevb.76.193309

We address the occurrence of conduction-band crossover in III-V self-assembled quantum dots solely due to misfit strain. Band structure analysis in terms of standard deformation-potential theory shows that Γ-X crossover can occur in the dot, while bo... Read More about Conduction-band crossover induced by misfit strain in InSb/GaSb self-assembled quantum dots.

Importance of aspect ratio over shape in determining the quantization potential of self-assembled zinc-blende III-V quantum dots (2007)
Journal Article
Rybchenko, S. I., Yeap, G., Gupta, R., Itskevich, I. E., & Haywood, S. K. (2007). Importance of aspect ratio over shape in determining the quantization potential of self-assembled zinc-blende III-V quantum dots. Journal of applied physics, 102(1), 013706. https://doi.org/10.1063/1.2752127

We have studied the effect of shape on the strain-modified electron/hole confinement potential in zinc-blende quantum dots (QDs), using standard deformation potential theory and an anisotropic continuum-elasticity approximation. Calculations were per... Read More about Importance of aspect ratio over shape in determining the quantization potential of self-assembled zinc-blende III-V quantum dots.

Development of a (silent) speech recognition system for patients following laryngectomy (2007)
Journal Article
Fagan, M. J., Ell, S. R., Gilbert, J. M., Sarrazin, E., & Chapman, P. M. (2008). Development of a (silent) speech recognition system for patients following laryngectomy. Medical engineering & physics, 30(4), 419-425. https://doi.org/10.1016/j.medengphy.2007.05.003

Surgical voice restoration post-laryngectomy has a number of limitations and drawbacks. The present gold standard involves the use of a tracheo-oesophageal fistula (TOF) valve to divert air from the lungs into the throat, which vibrates, and from thi... Read More about Development of a (silent) speech recognition system for patients following laryngectomy.

Assessing mechanical function of the zygomatic region in macaques: validation and sensitivity testing of finite element models (2006)
Journal Article
Kupczik, K., Dobson, C. A., Fagan, M. J., Crompton, R. H., Oxnard, C. E., & O'Higgins, P. (2007). Assessing mechanical function of the zygomatic region in macaques: validation and sensitivity testing of finite element models. Journal of anatomy, 210(1), 41-53. https://doi.org/10.1111/j.1469-7580.2006.00662.x

Crucial to the interpretation of the results of any finite element analysis of a skeletal system is a test of the validity of the results and an assessment of the sensitivity of the model parameters. We have therefore developed finite element models... Read More about Assessing mechanical function of the zygomatic region in macaques: validation and sensitivity testing of finite element models.

Three dimensional stereolithography models of cancellous bone structures from μCT data: Testing and validation of finite element results (2006)
Journal Article
Dobson, C. A., Sisias, G., Phillips, R., Langton, C. M., & Fagan, M. J. (2006). Three dimensional stereolithography models of cancellous bone structures from μCT data: Testing and validation of finite element results. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 220(3), 481-484. https://doi.org/10.1243/09544119H00405

Stereolithography (STL) models of complex cancellous bone structures have been produced from three-dimensional micro-computed tomography data sets of human cancellous bone histological samples from four skeletal sites. The STL models have been mechan... Read More about Three dimensional stereolithography models of cancellous bone structures from μCT data: Testing and validation of finite element results.

Tuning of electronic coupling between self-assembled quantum dots (2005)
Journal Article
Rybchenko, S., Itskevich, I., Skolnick, M. S., Cahill, J., Tartakovskii, A. I., Hill, G., & Hopkinson, M. (2005). Tuning of electronic coupling between self-assembled quantum dots. Applied physics letters, 87(3), 033104. https://doi.org/10.1063/1.1995953

Semiconductor self-assembled quantum dots (SAQDs) normally have zero-dimensional properties, but become coupled and acquire higher-dimensional character if the distance between the dots is small. Using photoluminescence spectroscopy under high hydros... Read More about Tuning of electronic coupling between self-assembled quantum dots.

High pressure as a tool to tune electronic coupling in self-assembled quantum dot nanostructures (2004)
Journal Article
Itskevich, I. E., Rybchenko, S. I., Andreev, A. D., Cahill, J., Tartakovskii, A. I., Skolnick, M. S., Hill, G., & Hopkinson, M. (2004). High pressure as a tool to tune electronic coupling in self-assembled quantum dot nanostructures. physica status solidi (b), 241(14), 3257-3262. https://doi.org/10.1002/pssb.200405235

High pressure provides an efficient way of controlling the electronic properties of semiconductor nanostructures. We use pressure to tune electronic coupling in stacks of self-assembled quantum dots (SAQDs). The coupling occurs as soon as the distanc... Read More about High pressure as a tool to tune electronic coupling in self-assembled quantum dot nanostructures.

A Comparative Study of Aortic Wall Stress Using Finite Element Analysis for Ruptured and Non-ruptured Abdominal Aortic Aneurysms*1 (2004)
Journal Article
VENKATASUBRAMANIAM, A., FAGAN, M., MEHTA, T., MYLANKAL, K., RAY, B., KUHAN, G., CHETTER, I., & MCCOLLUM, P. (2004). A Comparative Study of Aortic Wall Stress Using Finite Element Analysis for Ruptured and Non-ruptured Abdominal Aortic Aneurysms*1. European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery, 28(2), 168-176. https://doi.org/10.1016/S1078-5884%2804%2900178-9

Background. The decision to repair an asymptomatic abdominal aortic aneurysm (AAA) is currently based on diameter (greater than or equal to 5.5 cm) alone. However, aneurysms less than 5.5 cm do rupture while some reach greater than 5.5 cm without rup... Read More about A Comparative Study of Aortic Wall Stress Using Finite Element Analysis for Ruptured and Non-ruptured Abdominal Aortic Aneurysms*1.

A comparative study of aortic wall stress using finite element analysis for ruptured and non-ruptured abdominal aortic aneurysms (2004)
Journal Article
Venkatasubramaniam, A. K., Fagan, M. J., Mehta, T., Mylankal, K. J., Ray, B., Kuhan, G., Chetter, I. C., & McCollum, P. T. (2004). A comparative study of aortic wall stress using finite element analysis for ruptured and non-ruptured abdominal aortic aneurysms. European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery, 28(2), 168-176. https://doi.org/10.1016/j.ejvs.2004.03.029

Background. The decision to repair an asymptomatic abdominal aortic aneurysm (AAA) is currently based on diameter (≥5.5 cm) alone. However, aneurysms less than 5.5 cm do rupture while some reach greater than 5.5 cm without rupturing. Hence the need t... Read More about A comparative study of aortic wall stress using finite element analysis for ruptured and non-ruptured abdominal aortic aneurysms.