Marwa S. Al-Karadi
Multi-beat averaging reveals u waves are ubiquitous and standing tall at elevated heart rates following exercise
Al-Karadi, Marwa S.; Langley, Philip
Authors
Philip Langley
Abstract
The reporting of U wave abnormalities is clinically important, but the measurement of this small electrocardiographic (ECG) feature is extremely difficult, especially in challenging recording conditions, such as stress exercise, due to contaminating noise. Furthermore, it is widely stated that ECG U waves are rarely observable at heart rates greater than 90 bpm. The aims of the study were (i) to assess the ability of multi-beat averaging to reveal the presence of U waves in ECGs contaminated by noise following exercise and (ii) to quantify the effect of exercise on U wave amplitude. The multi-beat averaging algorithm was applied to recover U waves in 20 healthy subjects in pre- and post-exercise recordings. Average beats were generated from 30 beat epochs. The prevalence of U waves and their amplitudes were measured in pre- and post-exercise recordings and changes in amplitude due to exercise were quantified. U waves were present in all subjects in pre-exercise recordings. Following exercise, U waves could not be seen in standard ECG but were observable in all 20 subjects by multi-beat averaging and despite significantly increased mean (±SD) heart rate (63 ± 8 bpm vs. 100 ± 9 bpm, p < 0.0001). Furthermore, U waves were observable in all subjects with heart rates greater than 90 bpm. U waves significantly increased in amplitude following exercise (38 ± 15 μV vs. 80 ± 48 μV, p = 0.0005). Multi-beat averaging is effective at recovering U waves contaminated by noise due to exercise. U waves were measurable in all subjects, dispelling the myth that U waves are rarely seen at elevated heart rates. U waves exhibit increased amplitudes at elevated heart rates following exercise.
Citation
Al-Karadi, M. S., & Langley, P. (2020). Multi-beat averaging reveals u waves are ubiquitous and standing tall at elevated heart rates following exercise. Sensors, 20(14), 1-12. https://doi.org/10.3390/s20144029
Journal Article Type | Letter |
---|---|
Acceptance Date | Jul 18, 2020 |
Online Publication Date | Jul 20, 2020 |
Publication Date | Jul 2, 2020 |
Deposit Date | Jul 25, 2020 |
Publicly Available Date | Jul 27, 2020 |
Journal | Sensors (Switzerland) |
Electronic ISSN | 1424-8220 |
Publisher | MDPI |
Peer Reviewed | Peer Reviewed |
Volume | 20 |
Issue | 14 |
Article Number | 4029 |
Pages | 1-12 |
DOI | https://doi.org/10.3390/s20144029 |
Keywords | ECG U wave; ECG T wave; Multi-beat averaging algorithm; Exercise ECG; High heart rates |
Public URL | https://hull-repository.worktribe.com/output/3547453 |
Publisher URL | https://www.mdpi.com/1424-8220/20/14/4029 |
Files
Published article
(1.7 Mb)
PDF
Copyright Statement
© 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
You might also like
Validation of an algorithm to reveal the U wave in atrial fibrillation
(2018)
Journal Article
The effect of beat interval on ventricular repolarisation in atrial fibrillation
(2019)
Presentation / Conference Contribution
Heart sound classification from unsegmented phonocardiograms
(2017)
Journal Article
Downloadable Citations
About Repository@Hull
Administrator e-mail: repository@hull.ac.uk
This application uses the following open-source libraries:
SheetJS Community Edition
Apache License Version 2.0 (http://www.apache.org/licenses/)
PDF.js
Apache License Version 2.0 (http://www.apache.org/licenses/)
Font Awesome
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2025
Advanced Search