Skip to main content

Research Repository

Advanced Search

An evaluation of inkjet printed amino acid fingerprint test targets for ninhydrin process monitoring − and some observations

Croxton, Ruth; Kent, Terry; Littlewood, Anthony; Smith, Millicent

Authors

Ruth Croxton

Terry Kent

Anthony Littlewood

Millicent Smith



Abstract

Ninhydrin was implemented as the primary police method of developing latent fingermarks on paper, cardboard and some other porous surfaces from the late 1960s. Some researchers have used individual amino acids, or mixtures of amino acids, as a method of testing the effectiveness of reagent formulations. It was not however known whether simple mixtures of amino acids could effectively emulate latent fingermarks in reactions with reagents such as ninhydrin. The first part of this study compared the effects of ninhydrin fingermark treatments used internationally in various police laboratories on test targets created by inkjet printing graduated concentrations of a representative mixture of amino acids in a series of blocks on paper. Variations in intensity of development were observed between laboratories which used various formulations and heat and humidity post treatment protocols. In a further trial in 2015 several participants in the International Fingerprint Research Group (IFRG) meeting processed test targets in their own laboratories and submitted them for measurement. Again, variation in developed intensity was observed. The depletion of the activity of ninhydrin solutions during use was also investigated in early evaluations of the test targets. An established fingerprint laboratory then processed a number of samples from a batch of targets to examine batch consistency. This was followed by designing a new test target which enabled comparisons between the developed intensity of printed test target blocks alongside depletion series of split, natural donor fingermarks. A panel of 20 donors provided depletion fingermarks and four ninhydrin formulations and treatment protocols were used. The developed test target blocks were scanned, intensity of development measured, and the results compared with the fingermark development which was evaluated by three assessors using two types of scale. Good correlation between the intensity of the developed test targets and latent fingermark quality and intensity scores was observed with the four ninhydrin treatment protocols, including some which used deliberately downgraded ninhydrin concentrations. This type of evaluation was carried out a second time to investigate modified heat and humidity protocols. The use of such test targets for routine reagent quality control and process verification would appear to be far more accurate and reliable than the use of small numbers of donor fingermarks. It is not clear why the different ninhydrin formulations investigated in the latter part of the work have very different optimum post treatment heating regimes.

Citation

Croxton, R., Kent, T., Littlewood, A., & Smith, M. (2021). An evaluation of inkjet printed amino acid fingerprint test targets for ninhydrin process monitoring − and some observations. Forensic Science International, 321, Article 110741. https://doi.org/10.1016/j.forsciint.2021.110741

Journal Article Type Article
Acceptance Date Feb 19, 2021
Online Publication Date Feb 22, 2021
Publication Date 2021-04
Deposit Date Apr 19, 2021
Publicly Available Date Feb 23, 2022
Journal Forensic Science International
Print ISSN 0379-0738
Publisher Elsevier
Peer Reviewed Peer Reviewed
Volume 321
Article Number 110741
DOI https://doi.org/10.1016/j.forsciint.2021.110741
Keywords Ninhydrin; Inkjet-printing; Amino acid; ISO/IEC 17025; Accreditation; Fingermark