Skip to main content

Research Repository

Advanced Search

Development of an anatomically correct mouse phantom for dosimetry measurement in small animal radiotherapy research

Soultanidis, George; Subiel, Anna; Renard, Isaline; Reinhart, Anna Merle; Green, Victoria L.; Oelfke, Uwe; Archibald, Stephen J.; Greenman, John; Tulk, Amanda; Walker, Adrian; Schettino, Giuseppe; Cawthorne, Christopher J.

Authors

George Soultanidis

Anna Subiel

Isaline Renard

Anna Merle Reinhart

Uwe Oelfke

Amanda Tulk

Adrian Walker

Giuseppe Schettino

Christopher J. Cawthorne



Abstract

Significant improvements in radiotherapy are likely to come from biological rather than technical optimization, for example increasing tumour radiosensitivity via combination with targeted therapies. Such paradigms must first be evaluated in preclinical models for efficacy, and recent advances in small animal radiotherapy research platforms allow advanced irradiation protocols, similar to those used clinically, to be carried out in orthotopic models. Dose assessment in such systems is complex however, and a lack of established tools and methodologies for traceable and accurate dosimetry is currently limiting the capabilities of such platforms and slowing the clinical uptake of new approaches. Here we report the creation of an anatomically correct phantom, fabricated from materials with tissue-equivalent electron density, into which dosimetry detectors can be incorporated for measurement as part of quality control (QC). The phantom also allows training in preclinical radiotherapy planning and cross-institution validation of dose delivery protocols for small animal radiotherapy platforms without the need to sacrifice animals, with high reproducibility.

Mouse CT data was acquired and segmented into soft tissue, bone and lung. The skeleton was fabricated using 3D printing, whilst lung was created using computer numerical control (CNC) milling. Skeleton and lung were then set into a surface-rendered mould and soft tissue material added to create a whole-body phantom. Materials for fabrication were characterized for atomic composition and attenuation for x-ray energies typically found in small animal irradiators. Finally cores were CNC milled to allow intracranial incorporation of bespoke detectors (alanine pellets) for dosimetry measurement.

Citation

Soultanidis, G., Subiel, A., Renard, I., Reinhart, A. M., Green, V. L., Oelfke, U., …Cawthorne, C. J. (2019). Development of an anatomically correct mouse phantom for dosimetry measurement in small animal radiotherapy research. Physics in Medicine and Biology, 64(12), Article 12NT02. https://doi.org/10.1088/1361-6560/ab215b

Journal Article Type Article
Acceptance Date May 13, 2019
Online Publication Date Jun 21, 2019
Publication Date Jun 21, 2019
Deposit Date Jun 22, 2019
Publicly Available Date Jun 22, 2020
Journal Physics in Medicine & Biology
Print ISSN 0031-9155
Electronic ISSN 1361-6560
Publisher IOP Publishing
Peer Reviewed Peer Reviewed
Volume 64
Issue 12
Article Number 12NT02
DOI https://doi.org/10.1088/1361-6560/ab215b
Public URL https://hull-repository.worktribe.com/output/2023861
Publisher URL https://iopscience.iop.org/article/10.1088/1361-6560/ab215b

Files







You might also like



Downloadable Citations